DVM645BI GB 20
Resolution and Accuracy
DC Volts (mV DC)
Range resolution Accuracy (% reading + digits)
400mV 0.1mV ± (0.3% rdg + 5d)
4V 1mV ± (0.3% rdg + 2d)
40V 10mV ± (0.3% rdg + 2d)
400V 100mV ± (0.3% rdg + 2d)
1000V 1V ± (0.3% rdg + 2d)
Input impedance: 10MΩ, < 100pF
Overload Protection: 1000V DC or 750V AC RMS
AC Volts (true rms, ac-coupled)
Range resolution Accuracy (% reading + digits)
4V 1mV
40V 10mV
400V 100mV
750V 1V
± (0.8% rdg + 5d) 50 to 60Hz
± (1.2% rdg + 5d) 45 to 1kHz
Input impedance: 10MΩ, < 100pF
Overload Protection: 1000V DC or 750V AC RMS
AC coupled true RMS
DC Current
Range resolution Accuracy (% reading + digits)
4mA 1µA ± (0.8% rdg + 5d)
40mA 10µA ± (0.8% rdg + 5d)
400mA 100µA ± (0.8% rdg + 5d)
10A
(20A for 30
seconds)
10mA ± (1.5% rdg + 10d)
Input protection: 1A/250V fuse for mA input, 15A / 250V fuse for A input
Load voltage: 600mV max. for mA input, 900mV max. for A input
Comentários a estes Manuais